Model FC-BMBS
Single Inlet-Belt Drive
Performance Characteristics
- In these systems, the connection of the impeller to the motor is indirectly and via a pulley-belt.
- The design of these fan types is based on the impeller method between two bearings (Impeller Between Bearing) as well as (Impeller Overhung), according to the AMCA standard.
- The airflow capacity can reach up to approximately 360,000 cubic meters per hour.
- The static pressure can be up to about 5,000 pascals.
- The diameter of the fan impeller can reach up to 1600 millimeters.
- The inlet air volume can be adjusted using a damper or by changing the speed frequency.
- These series of fans can perform adequately in temperatures ranging from -40 to 500 degrees Celsius.
- The position of the outlet mouth relative to the inlet and its angle concerning the horizon can be chosen according to the AMCA standard.
- The capability of installing any accessories such as damper, silencer, bird screen, chassis, etc., is available for these air movers.
- These fans are primarily used in systems for collecting and transferring gases and polluted air.
- Based on the capacity and performance efficiency of the fan, the impeller blades of these fans can be designed as either Backward Curved or Backward Inclined.
- The vibration balance of these fans complies with the ISO standard DIN ISO 1940-1 grade G 6.3 <4 mm/s.
Special Design Methods
- In environments with high corrosion and acidity, stainless-steel 304 or stainless-steel 316 materials are used for the body and impeller of the fans (stainless-steel Fans).
- In the presence of flammable gases and dust in the fan’s environment, to prevent sparks and explosions, the fan is completely isolated from the surrounding environment, and additionally, a layer of copper or composite insulation is used on the potential contact area between the two-metal impeller and fan body (Explosion & Spark proof Fans).
- In the oil, gas, and petrochemical industries, centrifugal fans are designed and manufactured according to the international standards API 560 & API 673.